Electron Fluoride Solution Series

  1. Fluorocarbon cooling medium

Fluorocarbon cooling medium Description

Fluorocarbon-cooled working fluids are high-permeability, high- permeability perfluorinated liquid compounds with high dielectric constant, ideal chemical inertness, excellent thermal conductivity, and good system matching compatibility. This series of products are widely used in various temperature-controlled heat dissipation systems. This product is widely used in immersed phase liquid cooling of data center servers, and is also widely used in various stages of semiconductor manufacturing to cool and cool (such as wafer manufacturing coolers, dry Etching and tempering upper and lower electrodes for temperature control, wafer pattern preparation, exposure table, and wafer test system.

High and low temperature cooling control, etc.; high-speed train power supply inverter, lithium battery power car cooling temperature control, nuclear power, UHV power grid and military radar system, wind turbine internal heating components cooling system cooling and cooling.

Fluorocarbon cooling medium Features

Ideal chemical inertness, can be widely used in various temperature control heat dissipation occasions.

Single-phase cooling has a lower gas pressure, which can reduce the sealing requirements of the equipment and the maintenance in the later maintenance, and reduce the cost.

Non-dangerous goods or not explosion, no flash point

Electrical insulation is good, with a very high breakdown voltage greater than 50KV.

A dielectric constant below 2 does not deplete data in data center applications.

Good fluidity, low viscosity compared to clean water; good heat dissipation in temperature control systems.

Non-toxic, harmless and non-irritating

Fluorocarbon cooling medium Typical Properties

Dielectric constant 1.85
Breakdown voltage Content measurement) 48KV
Surface Tension 16.7mN/m
Boiling point 110~115°C
Density 1.812g/ml
Volume resistivity 1.4×1014
Coefficient of expansion 0.0015
Saturated water content 23.4ppm
Critical temperature ——
PH value ——
Flash point N/A
Burning process N/A
ODP 0
GWP Low
Specific heat (25 ° C) 1.431J/g°C
Thermal Conductivity 0.0831
Heat of vaporization 136J/g°C
Viscosity 0.87 mPa.s
  1. HH-705

HH-705 Description

Cooling Medium HH-705 is a highly stable fluoroether liquid with high dielectric strength, ideal chemical inertness, excellent heat transfer properties and good system compatibility. This product is widely used in various temperature control cooling systems, such as heat pipe cooling system (soaking plate, inflation plate and various types of heat pipe radiators), lithium battery power vehicles (motor, battery box, etc.) Cooling and cooling in all aspects of production and manufacturing (such as wafer manufacturing cooler, dry etching upper and lower electrode cooling temperature control, chip pattern preparation exposure machine, chip test system high and low temperature cooling control, chip sorting equipment, etc.), military Cooling and cooling of the heat dissipation system of the internal heating components of the radar system and the wind power generator.

HH-705 Features

It has good chemical inertness, it can be widely used in various temperature controlled heat dissipation applications.

Non-dangerous goods, no explosion, no flash point

Good electrical insulation, with a very high breakdown voltage greater than 40KV。

Low viscosity, good heat dissipation in the temperature control system.

Non-toxic, harmless and non-irritating

Environmentally friendly, with 0 ODP values and very low GWP value products

HH-705 Typical Properties

Name HH-705 Dielectric constant 5.82
Dielectric strength >40KV Surface Tension 1.154mN/m
Boiling point 73°C density 1.52g/ml
Specific heat capacity 137.5J/g°C Vaporization heat 132.7J/g°C
Saturated water content 647ppm Viscosity 0.61 CPS
PH Not applicable Flash point N/A
Combustion process; N/A ODP 0
GWP 33 Vapor Pressure 20℃ 13kpa
  1. Fluorocarbon alkane solvent

Fluorocarbon alkane solvent Usage

Solvent: anti-fingerprint liquid and lubricant thinner

Cleaning: metal degreasing cleaning, plastic cleaning, resin cleaning, dust

removal

Heat medium: secondary refrigerant, cold load

Used to replace 3MTM NovecTM, & DupontTM Vertrel® solvents

Fluorocarbon alkane solvent Advantages

Colorless, odorless, not burning

Low surface tension, low viscosity, low latent heat of evaporation

Excellent heat resistance, chemical resistance and hydrolysis resistance

The performance is closest to CFCs and the ODP value is zero

Fluorocarbon alkane solvent Typical Properties

Boiling point 90-110℃
density 1.766(g/ml,25℃)
Viscosity 0.62(cst)
Vapor Pressure 6(KPa, 25℃)
Perfluoro-n-heptane ≈27%
Perfluoropropylcyclohexyl ether ≈6%
Perfluorobutylcyclop entyl ether ≈36%
Perfluoro-n-octane ≈23%
Perfluorocyclodecyl ether ≈1.5%
Moisture <50ppm
  1. Hexafluoropropylene trimer

Hexafluoropropylene trimer Usage

Solvent: lubricant diluent

Cleaning: metal degreasing cleaning, plastic cleaning, resin cleaning, dust removal

Synthetic surfactants and polymers

Heat medium: secondary refrigerant, carrying cold

Used to replace 3MTM NovecTM, & DupontTM Vertrel® solvents

Hexafluoropropylene trimer Advantages

Colorless, odorless, not burning

Low surface tension, low viscosity, low latent heat of evaporation

Excellent heat resistance, chemical resistance and hydrolysis resistance

The performance is closest to CFCs and the ODP value is zero

Hexafluoropropylene trimer Typical Properties

Boiling point 108 ℃
density 1.75 (g/ml,25℃)
Viscosity 0.68 (cst)
Vapor Pressure 5.5 (KPa,25℃)